  • The 16 Most Commonly Used Parameters of Inverters ( II )
    Aug 12, 2023
    9. Electronic thermal overload protection This function is set to protect the motor from overheating. It is used by the CPU in the Inverter to calculate the temperature rise of the motor based on the operating current value and frequency, thereby providing overheating protection. This function is only applicable to "one to one" situations, and in "one to many" situations, thermal relays should be installed on each motor. Electronic thermal protection setting value (%)=[Motor rated current (A)/Inverter rated output current (A)] × 100%.   10. Frequency limitations The upper and lower limits of the frequency output amplitude of the Inverter. Frequency limit is a protective function designed to prevent incorrect operation or failure of external frequency setting signal sources, which may cause excessive or low output frequency, in order to prevent damage to equipment. Set according to the actual situation in the application. This function can also be used for speed limiting. For some belt conveyors, due to the limited amount of material conveyed, in order to reduce mechanical and belt wear, an Inverter can be used for driving, and the upper frequency limit of the Inverter can be set to a certain frequency value, which can make the belt conveyor run at a fixed and lower working speed.   11. Bias frequency Some are also called deviation frequency or frequency deviation setting. Its purpose is to adjust the output frequency when the frequency is set by an external analog signal (voltage or current), and this function can be used to adjust the output frequency when the frequency setting signal is at its lowest. When the frequency setting signal of some Inverters is 0%, the deviation value can be applied within the range of 0 to fmax, and some Inverters (such as Mingdian House and Sanken) can also set the bias polarity. If during debugging, when the frequency setting signal is 0%, the output frequency of the Inverter is not 0Hz, but xHz, then setting the bias frequency to a negative xHz can make the output frequency of the Inverter 0Hz.   12. Frequency setting signal gain This function is only effective when setting the frequency using an external analog signal. It is used to compensate for the inconsistency between the external set signal voltage and the internal voltage of the Inverter (+10v); At the same time, it is convenient to select signal voltage for analog settings. When the analog input signal is at its maximum (such as 10V, 5V, or 20mA), calculate the frequency percentage that can output the f/V graph and set it as a parameter; If the external signal is set to 0-5V, and the output frequency of the Inverter is 0-50Hz, set the gain signal to 200%.   13. Torque limitation It can be divided into two types: driving torque limit and braking torque limit. It is based on the output voltage and current values of the Inverter, and torque calculation is carried out by the CPU. It can significantly improve the impact load recovery characteristics during acceleration, deceleration, and constant speed operation. The torque limiting function can achieve automatic acceleration and deceleration control. Assuming that the acceleration and deceleration time is less than the load inertia time, it can also ensure that the motor automatically accelerates and decelerates according to the torque setting value. The drive torque function provides powerful starting torque. During steady-state operation, the torque function controls the motor slip and limits the motor torque to the maximum set value. When the load torque suddenly increases, even if the acceleration time is set too short, it will not cause the Inverter to trip. If the acceleration time is set too short, the motor torque will not exceed the maximum set value. A high driving torque is beneficial for starting, and setting it at 80-100% is more appropriate. The smaller the braking torque setting value, the greater the braking force, which is suitable for situations of rapid acceleration and deceleration. If the braking torque setting value is set too much, overvoltage alarm phenomenon may occur. If the braking torque is set to 0%, the total amount of regeneration applied to the main capacitor can approach 0, so that the motor can decelerate to a stop without tripping when decelerating without using the braking resistor. However, on some loads, such as when the braking torque is set to 0%, there may be a brief idle phenomenon during deceleration, causing the Inverter to repeatedly start and the current to fluctuate significantly. In severe cases, it may cause the Inverter to trip, and attention should be paid.   14. Acceleration and deceleration mode selection Also known as acceleration/deceleration curve selection. Generally, Inverters have three types of curves: linear, nonlinear, and S, and most of them choose linear curves; Nonlinear curves are suitable for variable torque loads, such as fans; The S-curve is suitable for constant torque loads, and its acceleration and deceleration changes are relatively slow. When setting, the corresponding curve can be selected based on the load torque characteristics, but there are exceptions. When debugging the Inverter of a boiler induced draft fan, the author first selects a non-linear curve for the acceleration and deceleration curve, and when the Inverter is operated together, it trips. Adjusting and changing many parameters has no effect, and then changing it to an S curve will be normal. The reason for this is that before starting, the induced draft fan rotates on its own due to the flow of flue gas and reverses to become a negative load. This selects the S-curve, which slows down the frequency rise speed at the beginning of the start, thus avoiding the occurrence of Inverter tripping. Of course, this is the method used for Inverters without DC braking function for starting.   15. Torque Vector Control Vector control is based on the theory that asynchronous motors and DC motors have the same torque generation mechanism. Vector control method is to decompose the stator current into specified magnetic field current and torque current, and control them separately, while outputting the combined stator current to the motor. Therefore, in principle, the same control performance as a DC motor can be obtained. By using torque vector control function, the motor can output maximum torque under various operating conditions, especially in the low-speed operating area. Nowadays, almost all Inverters adopt non feedback vector control. Due to the ability of Inverters to compensate for slip based on the magnitude and phase of the load current, the motor has very hard mechanical characteristics, which can meet the requirements for most occasions without the need to set a speed feedback circuit outside the Inverter. The setting of this function can be selected between valid and invalid according to the actual situation. The related function is slip compensation control, which is used to compensate for speed deviation caused by load fluctuations, and can add the slip frequency corresponding to the load current. This function is mainly used for positioning control.   16. Energy saving control Fans and water pumps both belong to reduced torque loads, meaning that as the speed decreases, the load torque decreases proportionally to the square of the speed. Inverters with energy-saving control functions are designed with a dedicated V/f mode, which can improve the efficiency of motors and Inverters. This mode can automatically reduce the output voltage of the Inverter based on the load current, thereby achieving energy-saving goals. It can be set to be effective or ineffective according to specific circumstances. It should be noted that the nine and ten parameters are very advanced, but some users are unable to enable these two parameters during equipment renovation, that is, the Inverter trips frequently after activation, and everything is normal after shutdown. The reason for this is that: (1) there is a significant difference in the parameters between the original motor and the motor required for the Inverter. (2) Insufficient understanding of parameter setting function, such as energy-saving control function can only be used in V/f control mode and cannot be used in vector control mode. (3) The vector control method has been enabled, but manual setting and automatic reading of motor parameters have not been carried out, or the reading method is incorrect.        Unleash the power of industrial automation with Rockss Automation, the leading provider of a diverse range of variable frequency drives, drivers, motors, and more. With our extensive inventory and dedicated repair team, we are your one-stop solution for all your industrial automation needs.
    Read More
  • How to Choose Siemens Motor Correctly for the Inverter?
    Jul 15, 2023
       How to choose a suitable Inverter for existing motors? There is a certain amount of knowledge and a little skill in this. As a professional electromechanical equipment service provider, Rockss Automation not only helps customers choose motors well, but also cannot make careless choices about motor control. So, let's analyze and analyze today how Siemens Inverters can be perfectly combined with Siemens motors. SIEMENS 6SE3211-5BA40 Inverter       The commonly used types of Siemens Inverters are as follows: 6SE6440, 430, and 420. Usually, the choice between these three is also meticulous. Here are a few points for everyone from Rockss Automation: 1. Products powered by 380-480VAC and without filters are commonly used in Siemens 440 series Inverters. Just find the corresponding model for the 440 series. 2. There are two types of product oils for partial power consumption: imported with original packaging and domestically produced. The price of domestically produced products is cheaper compared to pure imported products. 3. The power corresponding to the Inverter model refers to the high torque output power. 4. Generally, the standard Siemens Inverter is optional and does not include a control panel. The control panel needs to be ordered separately. The control panel includes both Chinese and English versions. The English control panel is a bit cheaper than the Chinese one. SIEMENS 1FK7101-5AF71-1SA0 Motor      As mentioned above, the 440 series Siemens Inverter commonly used for 380V voltage of domestic standard motors. So, how to choose a suitable 440 series frequency converter? 440 power range: 0.37-255kW. Among them, 0.12kW-200kW (CT constant torque); 0.12kW-250kW (VT variable torque). Generally speaking, the Inverter is matched according to the power of the motor, and the ratio is 1:1 original. If the distance between the heavy load and the Inverter is relatively long, the power of the Inverters one to two levels higher than the power of the motor. If a Inverters equipped with multiple motors, it is sufficient to choose one level higher than the motor power, which is not the total power of the motors carried.     When selecting a Inverter, the following parameters should generally be considered:   1. Power   Choose the high-power Inverter for the high-power motor. However, for special occasions such as high temperatures and altitudes, it can cause a reduction in the capacity of the frequency converter, making it easy for the Inverter to amplify by one gear.   2. Current The rated current of the Inverter is greater than the maximum current of the motor operation, and it is generally marked on the nameplate.   3. Supply voltage   Generally, low-voltage frequency converters have single-phase 220-240V, three-phase 380-480V power supply, etc. The specific selection is rated according to actual needs.   4. Load inertia   In some situations, such as most ventilation ducts, there is no requirement for the motor to stop in a timely manner, while in some transmission belts, it is required to stop in a timely manner, so it can also be used as a reference condition for selecting frequency converters. SIEMENS 6SE3210-7BA40 Inverter    A Siemens Inverter can control multiple motors. This application situation is commonly referred to as "one dragging many". It has been running for many years and rarely malfunctions. However, it is important to pay attention to the following points when dragging a frequency converter:    1. The control method must use linear V/F control    2. One drag multiple is only used in situations where there are no strict requirements for motor speed regulation;    3. The total rated current of each motor should be less than the rated current of the variable frequency;    4. Independent thermal relays should be installed on each motor.    5. The power of each motor should be consistent as much as possible    6. The differences in physical characteristics of each output circuit should be minimized, including:    A. Motor characteristics, such as speed;    B. Cable characteristics, such as cross-sectional area, length, and material.    7. If the motor characteristics are basically consistent and the cable length approaches the allowable limit length of the frequency converter, methods such as increasing the outlet reactor, reducing the switching frequency, and appropriately increasing the Inverter can be adopted.      For mid-range applications, customers usually consider Siemens or ABB when choosing frequency converters. Indeed, in certain high-end special industries such as lifting and steel rolling, I personally believe that using frequency converters from foreign brands such as Siemens will provide more protection and fewer malfunctions. It's a lot easier to use in the later stage.
    Read More

Need Help? leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
send

home

products

WhatsApp

Contact us